Lists asset owners planned outages for transmission equipment. This also includes details for transmission equipment that will not have an outage, but associated secondary equipment has an outage and a related constraint set may be invoked. This scenario is indicated by the ISSECONDARY field in the table.

Package

NETWORK

Visibility

Public

Table schema

Column Official MMS Datatype GR-MMS Datatype Comment
OUTAGEID numeric(15, 0) 🔑 int 🔑 ID uniquely identifying the outage
SUBSTATIONID varchar(30) 🔑 varchar(30) 🔑 The substation this equipment is located at
EQUIPMENTTYPE varchar(10) 🔑 varchar(10) 🔑 The type of equipment. Valid values are: LINE = Line TRANS = Transformer CB = Circuit breaker ISOL = Isolator CAP = Capacitor REAC = Reactor UNIT = Unit
EQUIPMENTID varchar(30) 🔑 varchar(30) 🔑 A unique identifier for this equipment at this substation, and based on its type
STARTTIME datetime(3) 🔑 datetime2(0) 🔑 The planned starting date and time of the outage
ENDTIME datetime(3) datetime2(0) The planned ending date and time of the outage
SUBMITTEDDATE datetime(3) datetime2(0) The date and time this outage was first submitted
OUTAGESTATUSCODE varchar(10) varchar(10) A code representing the status of the outage. The OUTAGESTATUSCODE table will store a detailed description of each code.
RESUBMITREASON varchar(50) varchar(50) Changes to an outage key details may require the outage to be resubmitted. A new outage id will then be allocated and the outage will be reassessed. This field will detail the reason for the change.
RESUBMITOUTAGEID numeric(15, 0) int The new outage id created from a resubmit.
RECALLTIMEDAY numeric(10, 0) int The recall time in minutes during the day
RECALLTIMENIGHT numeric(10, 0) int The recall time in minutes during the night
LASTCHANGED datetime(3) datetime2(0) The time that this record was last changed
REASON varchar(100) varchar(100) The reason provided by the asset owner for this outage
ISSECONDARY numeric(1, 0) tinyint 1 = The outage is for a secondary piece of equipment that has an associated constraint set. The transmission equipment is still in service. 0 = The outage is for the transmission equipment
ACTUAL_STARTTIME datetime(3) datetime2(0) The actual starting date/time of the outage
ACTUAL_ENDTIME datetime(3) datetime2(0) The actual ending date/time of the outage
COMPANYREFCODE varchar(20) varchar(20) The asset owners reference code for this outage
ELEMENTID numeric(15, 0) 🔑 bigint 🔑 Equipment element id

Official MMS data model indexes

Index name Index type Index columns (in order)
NETWORK_OUTAGEDETAIL_LCX nonclustered LASTCHANGED
PK_NETWORK_OUTAGEDETAIL clustered, unique, primary key OUTAGEID, ELEMENTID, SUBSTATIONID, EQUIPMENTTYPE, EQUIPMENTID, STARTTIME

GR-MMS data model indexes

Index name Index type Index columns (in order)
IX_NETWORK_OUTAGEDETAIL_LASTCHANGED nonclustered LASTCHANGED
PK_NETWORK_OUTAGEDETAIL clustered, unique, primary key OUTAGEID, ELEMENTID, SUBSTATIONID, EQUIPMENTTYPE, EQUIPMENTID, STARTTIME

Historical-MMS data model indexes

Index name Index type Index columns (in order)
IX_NETWORK_OUTAGEDETAIL_LASTCHANGED nonclustered LASTCHANGED
PK_NETWORK_OUTAGEDETAIL clustered, unique, primary key OUTAGEID, ELEMENTID, SUBSTATIONID, EQUIPMENTTYPE, EQUIPMENTID, STARTTIME